Force-Deflection Curve (DIN 6796)
Force-deflection curve for DIN 6796 conical spring washers. Low h₀/t ratio (0.28-0.35) yields near-linear behavior; full flattening is the design working point. Computed via F-6796-A002.
Standard Condition Curve
Curve variants across specs × materials. Register to view.
Standard Condition Curve
| Parameter | Value | Unit |
|---|---|---|
| De | 28 | mm |
| Di | 14.2 | mm |
| h₀ | 0.45 | mm |
| Material | C67S | — |
| t | 1.5 | mm |