| Outside diameterD / De | 150.11 mm (-0.4/+0 mm); limits 149.71–150.11 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Inside diameterd / Di | 81.03 mm (+0/+0.35 mm); limits 81.03–81.38 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Product thicknesst / t′ | 7.49 mm (-0.1/+0.1 mm); limits 7.39–7.59 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 13(PDF 15) |
|---|
| Free heightH0 / l₀ | 11.7 mm (-0.3/+0.3 mm); limits 11.4–12 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 13(PDF 15) |
|---|
| Cone heighth0 / h₀ | 4.27 mm (-0.46/+0.34 mm); limits 3.81–4.61 mmWorst-case envelope derived from free-height and plain product thickness t tolerances; it is a reference, not an independent standard h0 acceptance tolerance. | Derived reference | DIN-EN-16983-2017-09EN 16983 page 13(PDF 15); EN 16983 page 13(PDF 15) |
|---|
| Coaxiality— | ≤ 0.8 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Flatness— | Set by approved drawing, process card or supply agreementThe standard does not provide a universal independent numeric tolerance; an approved drawing, process card or supply agreement must provide the acceptance value. | Agreement required | POLYSPLENDID-INSPECTION-POLICY-2026-08Task 121 标准原文核对结论 |
|---|
| Parallelism— | Set by approved drawing, process card or supply agreementThe standard does not provide a universal independent numeric tolerance; an approved drawing, process card or supply agreement must provide the acceptance value. | Agreement required | POLYSPLENDID-INSPECTION-POLICY-2026-08Task 121 标准原文核对结论 |
|---|
| Test loadFt | 93492.722 N (-5/+5%); limits 88818.0859–98167.3581 NThe nominal test load comes from the current published standard, manufacturer, or engineering dataset; limits use the applicable DIN EN 16983 percentage tolerance. | Resolved | DIN EN 16983:2017-09approved_manufacturer_f75 |
|---|
| Hardness— | 42–52 HRCThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 11(PDF 13) |
|---|