| Outside diameterD / De | 160 mm (-0.4/+0 mm); limits 159.6–160 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Inside diameterd / Di | 82 mm (+0/+0.35 mm); limits 82–82.35 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Product thicknesst / t′ | 4.15 mm (-0.15/+0.05 mm); limits 4–4.2 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 13(PDF 15) |
|---|
| Free heightH0 / l₀ | 9.9 mm (-0.15/+0.3 mm); limits 9.75–10.2 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 13(PDF 15) |
|---|
| Cone heighth0 / h₀ | 5.6 mmFor this supplementary geometry, h0 follows the catalog nominal base thickness t. The finished t-prime tolerance is not reused to invent an independent h0 acceptance limit. | nominal_reference_only | DIN-EN-16983-2017-09Supplementary catalog geometry with DIN EN 16983 general tolerance basis |
|---|
| Coaxiality— | ≤ 0.8 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Flatness— | Set by approved drawing, process card or supply agreementThe standard does not provide a universal independent numeric tolerance; an approved drawing, process card or supply agreement must provide the acceptance value. | Agreement required | POLYSPLENDID-INSPECTION-POLICY-2026-08Task 121 标准原文核对结论 |
|---|
| Parallelism— | Set by approved drawing, process card or supply agreementThe standard does not provide a universal independent numeric tolerance; an approved drawing, process card or supply agreement must provide the acceptance value. | Agreement required | POLYSPLENDID-INSPECTION-POLICY-2026-08Task 121 标准原文核对结论 |
|---|
| Test loadFt | 21843 N (-5/+10%); limits 20750.85–24027.3 NThe nominal test load comes from the current published standard, manufacturer, or engineering dataset; limits use the applicable DIN EN 16983 percentage tolerance. | Resolved | DIN EN 16983:2017-09Extra row 31 |
|---|
| Hardness— | 42–52 HRCThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 11(PDF 13) |
|---|