| Outside diameterD / De | 249.94 mm (-0.46/+0 mm); limits 249.48–249.94 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Inside diameterd / Di | 127 mm (+0/+0.4 mm); limits 127–127.4 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Product thicknesst / t′ | 11.25 mm (-0.1/+0.1 mm); limits 11.15–11.35 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 13(PDF 15) |
|---|
| Free heightH0 / l₀ | 19.3 mm (-0.3/+0.3 mm); limits 19–19.6 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 13(PDF 15) |
|---|
| Cone heighth0 / h₀ | 8.16 mm (-0.51/+0.29 mm); limits 7.65–8.45 mmWorst-case envelope derived from free-height and plain product thickness t tolerances; it is a reference, not an independent standard h0 acceptance tolerance. | Derived reference | DIN-EN-16983-2017-09EN 16983 page 13(PDF 15); EN 16983 page 13(PDF 15) |
|---|
| Coaxiality— | ≤ 0.92 mmThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 12(PDF 14) |
|---|
| Flatness— | Set by approved drawing, process card or supply agreementThe standard does not provide a universal independent numeric tolerance; an approved drawing, process card or supply agreement must provide the acceptance value. | Agreement required | POLYSPLENDID-INSPECTION-POLICY-2026-08Task 121 标准原文核对结论 |
|---|
| Parallelism— | Set by approved drawing, process card or supply agreementThe standard does not provide a universal independent numeric tolerance; an approved drawing, process card or supply agreement must provide the acceptance value. | Agreement required | POLYSPLENDID-INSPECTION-POLICY-2026-08Task 121 标准原文核对结论 |
|---|
| Test loadFt | 214817.966 N (-5/+5%); limits 204077.0677–225558.8643 NThe nominal test load comes from the current published standard, manufacturer, or engineering dataset; limits use the applicable DIN EN 16983 percentage tolerance. | Resolved | DIN EN 16983:2017-09approved_manufacturer_f75 |
|---|
| Hardness— | 42–52 HRCThis supplementary geometry is outside the A/B/C dimension tables; dimensional tolerances, coaxiality, hardness and guide clearances use the applicable DIN EN 16983 general range rules. | Resolved | DIN EN 16983:2017-09EN 16983 page 11(PDF 13) |
|---|